GX-1-SH-5K Replacement Guide: RL35023S, SQB SS, Revere 9123 & 65023SS
- pete8781
- Jul 30
- 2 min read
Call (832) 290-3120 or email mnmscales@yahoo.com to confirm the exact replacement model and capacity.
GX-1-SH-5K Replacement Guide
MNM publishes the GX-1-SH-5K alongside interchange families Artech SS30310, Celtron SQB SS, HBM B35, Revere 9123, Rice Lake RL35023S, RL39123, Sensortronics 65023SS and Coti Global CG-23SS. Use that list to narrow the search, then match the actual 5,000 lb sensor details.
Eight things to match before ordering
1) 5,000 lb rated capacity. 2) Mounting length and loaded height. 3) Hole pattern, threads and hardware. 4) Load direction and cable exit. 5) 3 mV/V nominal signal. 6) Approximately 385 Ω input and 350 Ω output bridge values as published for this GX cell. 7) Wiring and connector/termination. 8) Stainless/environmental and approval requirements. A mismatch in any one can turn a simple replacement into a mechanical or calibration problem.
Replacing one cell in a four-cell platform
If only one cell failed, inspect why it failed. A bent foot, forklift impact, cable damage or washdown intrusion can affect nearby components too. After replacement, compare the four corner readings. If the new cell response is within the expected family but the corner is still wrong, examine load sharing and junction-box trim before condemning the sensor.
NTEP and commercial scale repairs
MNM identifies this model as NTEP, but an NTEP cell does not automatically make a repaired scale legal for trade. The certified scale configuration, indicator, load-cell certificate relationships, division settings, sealing and local weights-and-measures requirements may apply.
Recalibration is required
Any load-cell replacement should be followed by wiring verification, zero, corner balance, junction-box trim if needed, known-load span and multi-point checks. Record repeatability and return-to-zero results before putting a heavy floor scale or vessel back in service.
Main guide: https://www.allscalesusa.com/post/mnm-gx-1-sh-5k-5000-lb-stainless-ntep-shear-beam-guide Calibration: https://www.allscalesusa.com/post/how-to-calibrate-gx-1-sh-5k-floor-scale-load-cell MNM product: https://mnmscales.com/product/gx-1-sh-5k-stainless-steel-washdown-shear-beam-load-cell-5000-lb-ntep-moisture/