Need help matching an existing load cell? Call MNM Scales at (832) 290-3120 or email mnmscales@yahoo.com with the old model number, capacity and photos.

The MNM Scales 2,500 lb S-type load cell replacement is specifically listed by MNM as interchangeable with Celtron STC, Rice Lake RL20001, Sensortronics 60001 and Coti Global CG-SB product families. For scale owners and service technicians, that is important because these S-beam families are widely used in mechanical-scale conversions, suspended weighing, hopper/tank systems and industrial tension applications. The MNM cell’s 3 mV/V output, approximately 385-ohm input resistance, 350-ohm output resistance and standard red/black/green/white wiring also align closely with common 2,500 lb versions of these families.

MNM alloy-steel 2500 lb S-beam replacement load cell

Rice Lake RL20001 2,500 lb Comparison

Rice Lake’s current RL20001I 2,500 lb model is a 3.0 mV/V alloy-steel S-beam with 20 ft cable, 350-ohm output resistance and 385-ohm input resistance. Rice Lake lists the 2,500–3,000 lb body family with 1/2-20 UNF threads and NTEP approval under Certificate 91-046. Its wiring is Red +Excitation, Black -Excitation, Green +Signal and White -Signal. Those published values explain why the RL20001 is a natural interchange target for the MNM cell.

Sensortronics 60001 Comparison

Sensortronics Model 60001 is another long-established alloy-steel S-beam family with 2,500 lb capacity available, 3.0 mV/V nominal output, NTEP Class III/IIIL configurations and applications that include tank, bin and hopper weighing, hanging scales, lever conversions and tension/compression measurement. Its published datasheet shows a 350-ohm-class output bridge and similar excitation range, making it another logical replacement family identified directly by MNM.

S-beam geometry reference for 2500 lb industrial replacement load cell installations

Celtron STC and Coti Global CG-SB

Celtron STC is another 3 mV/V-class S-beam family widely used for batching, filling, hopper/tank weighing and scale conversion. MNM also names Coti Global CG-SB as an interchange. When replacing any of these, the goal is not just matching capacity: the installation needs the correct mechanical thread/space, excitation and signal range, wiring arrangement and NTEP status required by the finished scale. MNM’s explicit interchange list provides the starting model match; calibration finishes the conversion.

Electrical Match Checklist

The MNM sensor is rated 3.00 ± 0.01 mV/V, 385 ± 15 ohm input and 350 ± 5 ohm output. Wiring is Red +Excitation, Black -Excitation, Green +Signal and White -Signal. If the old load cell uses the same conventional colors, still verify the indicator terminal labels rather than wiring only by color. If signal polarity is reversed, the displayed load can move negative when force is applied; swap the signal pair rather than excitation if the indicator documentation confirms the wiring.

Mechanical Installation and Recalibration

Unload and secure the scale before removing the old S-beam. Preserve or correctly reinstall rod-end bearings, clevises and tension mounts so the new cell receives axial force. Avoid twisting the cable as the threaded connections are tightened. After installation, perform zero and span calibration with suitable reference loads. A nominal 3 mV/V match does not eliminate the need for recalibration because individual rated-output tolerances and mechanical installation affect the finished scale factor.

Legal-for-Trade Replacement Work

If the scale is used to buy, sell or charge by weight, preserve the required NTEP configuration and have the finished system calibrated and placed back into service according to local weights-and-measures rules. Replacing a failed NTEP component with another appropriate NTEP load cell is part of the process, but commercial approval applies to the working system rather than the load cell in isolation.

FAQ

Does MNM specifically list RL20001 as interchangeable?

Yes. The MNM product page names Rice Lake RL20001 along with Celtron STC, Sensortronics 60001 and Coti Global CG-SB.

Do I need to recalibrate after replacement?

Yes. Always recalibrate the finished scale after changing its load cell.