MS-1-SSH Replacement Guide: Matching a 5,000 lb Stainless NTEP S-Type Load Cell

Phone: (832) 290-3120

Email: mnmscales@yahoo.com

Contact MNM Scales with the old load cell model, label photo, dimensions and indicator model before ordering a replacement.

MS-1-SSH Replacement Guide: Matching a 5,000 lb Stainless NTEP S-Type Load Cell

A 5,000 lb capacity label is not enough to prove one S-type load cell can directly replace another. The MS-1-SSH replacement decision should cover mechanical fit, electrical match, application direction, environmental needs and—when used commercially—approval status.

Seven items to compare before ordering

  1. Capacity and application load case: both sensors may say 5,000 lb, but shock and overload requirements still matter.

  2. Overall geometry: body height, width and centerline must fit the existing assembly.

  3. Thread size and thread depth at both ends.

  4. Rated output in mV/V and the indicator’s calibration/configuration range.

  5. Bridge/input/output resistance and excitation compatibility.

  6. Cable length, conductor count, shielding, connector and polarity.

  7. NTEP certificate/application details when the scale is used for commercial transactions.

Do not assume a related MS-1 capacity is electrically identical

Related MS-1 stainless models are useful for understanding the family, but the safest replacement practice is to use the exact 5,000 lb MS-1-SSH label or certificate for electrical and dimensional values. This avoids turning a family-level specification into an unsupported exact-model claim.

What to do after the physical swap

  • Inspect the load path for binding before applying power or load.

  • Verify excitation and signal wiring before connecting the indicator.

  • Check that unloaded output is stable and changes smoothly with a small test load.

  • Perform zero/span calibration and multi-point verification.

  • For commercial scales, complete any required sealing, documentation or weights-and-measures process.

See the calibration guide for the post-installation verification sequence.

FAQ

Can I splice the old cable onto the new sensor? Splicing can be technically possible but can affect resistance, shielding, environmental sealing and metrological performance. Follow the load-cell and indicator manufacturer guidance.

Does the connector pinout always match wire color? No. Verify function/pinout rather than assuming colors or connector positions are universal.

Should I replace load hardware at the same time? Inspect rod ends, shackles, bolts and adapters for wear, deformation or corrosion; load-cell replacement is a good time to correct mechanical problems.

Buy the MS-1-SSH

 
 
 