A&D EW-150i 30/60/150 g Triple-Range Precision Balance Guide
Need more details or help choosing the correct item? Call MNM Scales at (832) 290-3120 or email mnmscales@yahoo.com.
A&D EW-150i 30/60/150 g triple-range precision balance automatically changes readability as the load crosses its three ranges: 30 g × 0.01 g, 60 g × 0.02 g and 150 g × 0.05 g. The model is built for light laboratory samples, jewelry production, electronics, formulation, parts counting and portable QC, with standard RS-232C, ACAI counting, percent and comparator functions. For U.S. legal status, the exact answer is important: EW-150i is not listed in current NTEP CoC 04-019A3, whose EW models are EW-1500i and EW-12Ki. Some A&D materials in other countries discuss trade-approved EW-150i configurations, but those foreign approvals should not be presented as U.S. NTEP certification.

How triple-range weighing works
The EW-150i does not use one fixed division across all 150 g. From zero through the first range it displays 0.01 g increments; the middle range uses 0.02 g; the upper range uses 0.05 g. This gives finer visibility for small samples without forcing the entire 150 g capacity to operate at the smallest division. Buyers should compare the range in which their normal sample falls, not simply quote “0.01 g” as if that readability applies at full capacity.
Exact MNM specifications
MNM lists 30/60/150 g capacities with 0.01/0.02/0.05 g readabilities, a 110 mm diameter stainless pan, 10 display updates per second and a 150 g default calibration mass. Linearity and repeatability track each range: ±0.01/±0.02/±0.05 g linearity and 0.01/0.02/0.05 g repeatability. The balance weighs about 1.1 kg and uses an AC adapter or optional rechargeable battery pack.
U.S. NTEP status: not listed on current CoC 04-019A3
Current U.S. CoC 04-019A3 lists EK-600i, EK-1200i, EK-6000i, EK-12Ki, EW-1500i and EW-12Ki. EW-150i is not in that model table. For a U.S. buyer, that means this exact EW-150i should be treated as a non-NTEP process balance unless a separate applicable U.S. certificate is established for the exact supplied configuration. Foreign trade-verification literature does not substitute for U.S. NTEP type evaluation.
Counting, percent and comparator functions
ACAI counting supports about 15,000 displayed pieces with a 0.01 g minimum unit weight and samples of 5, 10, 25, 50 or 100. Percent mode uses a 1 g minimum 100% reference. Comparator HI/OK/LO status helps with internal fill and acceptance work. These features make EW-150i useful in small-component production where the same station needs weighing, counting and relative comparison rather than only a single mass value.
RS-232C and battery portability
Standard RS-232C supports computers, printers and data loggers. A&D’s current U.S. EK/EW family page advertises roughly 250 hours with the current optional rechargeable battery, while older manuals describe earlier battery hardware with much shorter runtime. For a current purchase, confirm the battery pack supplied and use current manufacturer literature rather than assuming an older runtime specification applies.
External calibration
MNM lists 150 g as the default calibration mass. Level the balance, allow it to acclimate, calibrate with a suitable known reference and verify with independent values in the ranges the process actually uses. Because each range has a different division and performance specification, verification at a small load and a larger load can be more informative than a single full-scale check.
Frequently asked questions
What are the three EW-150i ranges? 30 g × 0.01 g, 60 g × 0.02 g and 150 g × 0.05 g. Is EW-150i NTEP in the U.S.? It is not listed on current CoC 04-019A3. Can it count parts? Yes, about 15,000 pieces when capacity allows. Minimum unit weight? 0.01 g. Does it have RS-232C? Yes. What is the default calibration mass? 150 g. Does the 0.01 g readability apply all the way to 150 g? No; the upper range is 0.05 g.




Comments