The A&D FC-10Ki inventory counting scale is built for stockrooms and production teams that need fast piece counts from weight rather than manual one-by-one counting. It handles up to 10 kg / 20 lb on its internal platform, displays weight in 1 g / 0.002 lb divisions, stores up to 500 item records and can calculate counts up to 1,000,000 pieces. Its fine-mode 0.01 g minimum unit weight is a counting-algorithm capability, not a 0.01 g weighing display. That distinction lets buyers understand where FC-10Ki is strong: repeatable bulk counts of small uniform items, not precision laboratory weighing or NTEP trade transactions.

Fasteners, washers, screws and small hardware

Hardware is a classic counting-scale application because pieces are usually numerous, relatively uniform and inconvenient to count manually. Tare the empty bin, build a representative sample and let ACAI refine average unit weight as more pieces are added. Very light screws or washers may require fine counting mode, but do not interpret a 0.01 g fine-mode unit-weight value as a direct single-piece weighing measurement. Validate the final setup against a known hand-counted quantity before using it for large inventory adjustments.

Kitting and assembly-line material control

For kits that require a fixed number of clips, fittings, electronic components or hardware, store the item’s unit weight and tare in memory, then use the count display as the operator adds parts. The three-display layout keeps total weight, unit weight and count visible at the same time. A kit can be checked by total count without manually sorting every piece. For mixed kits, count each homogeneous part separately; a counting scale cannot distinguish different parts with overlapping masses in one mixed container.

Cycle counting in warehouses

Battery operation lets a counting station move to shelves and bins during cycle counts. Save frequently counted SKUs in the 500 memories to reduce setup time. Re-level and verify after moving the scale. When an item’s supplier, material or revision changes, re-sample its average piece weight instead of blindly reusing old memory. A few tenths of a percent change in unit mass can become a large count error on thousands of pieces.

Receiving and supplier verification

Receiving teams can compare a supplier’s stated piece count with a weight-derived count before stocking. If a discrepancy appears, improve the sample and manually verify a smaller subset before rejecting the lot. Packaging, oil, coatings or moisture can change gross weight, so tare the actual container and establish unit weight from the same lot when possible. Counting by weight is a powerful screening method, but the operator should understand what variability the product introduces.

Choose the sample size based on part variability

FC-i supports standard 10-piece sampling plus 5, 25, 50, 100 and random sample quantities. A five-piece sample can be fast for heavy uniform parts; a 50- or 100-piece sample is usually better for very light or slightly variable parts. The larger total sample mass gives the scale more information and reduces the influence of one unusually heavy/light part. Let ACAI continue refining unit weight as additional pieces are added.

Normal versus fine minimum unit weight

Normal mode specifies a 0.2 g minimum unit weight. Fine mode can accept a calculated unit weight down to 0.01 g. Fine mode is useful for tiny parts, but the underlying main scale still displays weight in 1 g increments. Counting accuracy therefore depends heavily on a sufficiently large sample and consistent parts. If you actually need to weigh one 0.01 g component and report its mass, use a true precision balance rather than FC-10Ki.

Remote platform for larger containers

FC-05i lets the FC counting system use an external platform for larger bins or higher-capacity loads. This can create a two-scale workflow: use the internal platform to establish fine average piece weight, then use a larger remote scale for the bulk container. The remote scale must be configured/calibrated for its own capacity and resolution; its performance is not automatically the same as the internal 10 kg platform.

Barcode, PC and printer workflows

Standard RS-232C can feed counts, unit weights or weighing data to supported printers, computers or warehouse applications. Optional serial expansion provides additional ports. A robust workflow associates the saved memory code with the correct SKU, verifies the unit weight, captures count plus timestamp/operator if needed and defines what happens if communication fails. Data integration can remove transcription errors, but only if the software and scale are configured to agree on the record format.

When FC-10Ki is not the right tool

Choose a precision balance if the task is measuring individual milligram/tenth-gram masses rather than counting. Choose a higher-capacity counting platform if gross containers exceed 20 lb, or use the appropriate remote platform. Choose a legal-for-trade scale if the weight directly determines a commercial sale. Choose vision/RFID or another system when parts vary too much in weight for weight-based counting to be reliable. FC-10Ki excels when parts are reasonably uniform and the goal is fast internal inventory accuracy.

Frequently asked questions

Is FC-10Ki good for fasteners and hardware? Yes. How many SKUs can it store? Up to 500 item memories. What sample sizes are available? 5, 10, 25, 50, 100 and random sample quantities. What is the normal minimum piece weight? 0.2 g. Fine-mode minimum? 0.01 g. Does that mean the weighing display is 0.01 g? No; weight readability is 1 g / 0.002 lb. Can it connect to a larger platform? Yes, with FC-05i. Is it NTEP? No. Can it send data to a PC/printer? Yes, RS-232C is standard.

 
 
 