MNM Scales 20,000 lb x 2 lb Load Cell for Heavy Rigging, Hoist & Proof-Load Testing

Jul 29
2 min read

Questions about capacity or fixture selection? Call MNM Scales at (832) 290-3120 or email mnmscales@yahoo.com.

The MNM Scales 20,000 lb x 2 lb load cell can be used as the measuring element in controlled heavy rigging, hoist and proof-load test setups where the force path can be routed axially through an S-type transducer. The 2 lb display increment is well matched to many heavy industrial checks where maximum or steady load is measured in thousands of pounds.

Where This System Fits

Useful applications include internal maintenance checks, fixture validation, suspended-load research, comparison testing after hoist service, fabricated lifting-device evaluation and controlled force studies. It can also help document peak tension during an engineered test. The load cell measures force; it does not by itself certify a crane, hoist, sling, anchor or lifting accessory.

Why Axial Alignment Matters

S-beams are designed for force through their primary axis. Side load, torsion and bending can create error and unintended mechanical stress. Use appropriately rated clevises, eye hardware or self-aligning fixtures, and ensure the surrounding structure does not force the sensor into an angle as the load increases.

Peak Hold for Dynamic Maximums

Starting a hoist or taking slack out of rigging can create a momentary maximum higher than the settled load. Peak Hold lets the operator capture the highest observed value. For formal time-history analysis or cycle testing, a dedicated data-acquisition setup may be more appropriate; Peak Hold is best for simple maximum-force checks.

Digital indicator reference for capturing peak force in heavy rigging and hoist testing

Proof-Load Testing: Measurement Is Only One Part

A proof-load procedure may be governed by equipment manufacturer requirements, industry standards, regulations or an engineering test plan. The load cell can provide the force value, but the required proof percentage, hold duration, inspection method, exclusion zone and pass/fail criteria must come from the applicable procedure. Never infer a working-load limit solely from the number shown on the indicator.

Related Technical Guide

Frequently Asked Questions

Can this be used for a hoist test?

Yes, as force-measurement equipment in a controlled setup within the system rating, provided the hoist, rigging, fixture and procedure are independently suitable for the test.

Can it certify rigging?

No. It provides measured force data. Certification and inspection requirements depend on the equipment, governing standard and qualified personnel.

 
 
 