For replacement matching, send MNM Scales the old model number, photos and dimensions: (832) 290-3120 or mnmscales@yahoo.com.

A 10,000 lb S-type load cell replacement should be selected from the full mechanical and electrical interface, not capacity alone. The MS-1-10K publishes a 3.00 ± 0.01 mV/V output and 350 Ω-class bridge, but body dimensions, thread size, installed height, material, environmental sealing and cable arrangement can differ among 10K S-beams.

Mechanical Match

Measure the old cell's overall body, mounting-thread diameter and pitch, attachment spacing, cable exit and installed centerline. Compare how the fixture self-aligns under tension or compression. A replacement that is electrically correct but mechanically taller or shorter can alter the force path or prevent the assembly from fitting.

Electrical Match

For the MS-1-10K, compare the roughly 3 mV/V rated output, 385 Ω input resistance, 350 Ω output resistance and four-wire connection. Do not assume wire colors transfer from another brand. Confirm the replacement's own wiring documentation before powering the bridge.

Environment and Material

The standard MS-1-10K is alloy steel. If the original load cell is stainless, hermetically sealed or used in washdown/corrosive service, do not downgrade environmental protection just because capacity and signal match. MNM also sells a stainless/NTEP 10,000 lb S-type model for harsher applications.

Recalibration Is Mandatory Best Practice

After replacement, verify zero and span with known loads and check multiple points. A sensor's exact mV/V output can vary within specification, so a prior calibration should not simply be assumed correct after changing the transducer.

 
 
 