For replacement help, indicator matching or force-system questions, call MNM Scales at (832) 290-3120 or email mnmscales@yahoo.com.

The MNM MS-1-10K 10,000 lb S-type load cell is a bare alloy-steel tension/compression sensor for heavy test stands, crane-scale repairs, suspended weighing, cable tension and OEM force-measurement systems. It uses a standard millivolt strain-gauge bridge, so the sensor must be paired with a compatible indicator, amplifier or controller and calibrated after installation.

MS-1-10K Technical Specifications

MNM publishes rated output of 3.00 ± 0.01 mV/V, nonlinearity of ±0.02% FS, hysteresis of ±0.02% FS, repeatability of ±0.01% FS and 30-minute creep of ±0.02% FS. Input resistance is 385 ± 15 Ω and output resistance is 350 ± 5 Ω. Insulation resistance is at least 5000 MΩ and the published excitation voltage is 10 V DC/AC.

The compensated temperature range is -10°C to 50°C, operating range is -20°C to 60°C and safe overload is listed at 120% FS. Cable length is 20 ft. Wiring is red +excitation, black -excitation, green +signal and white -signal.

Four-wire S-type load cell wiring reference for the MNM MS-1-10K

Why a 10,000 lb S-Beam Is Useful

Ten-thousand-pound capacity gives useful headroom for heavy cable and chain testing, suspended equipment, hydraulic or electromechanical test stands and crane-scale rebuilds while remaining much smaller and easier to integrate than many high-capacity compression-only sensors. The tradeoff is that a large-capacity cell may provide less signal change for very small forces, so capacity should be chosen around the real working range rather than simply buying the largest sensor available.

Installation and Indicator Matching

Keep the load axial and minimize bending, torsion and side force. Match the thread size, body dimensions and installed height before treating another 10K S-beam as a drop-in substitute. Electrically, use a strain-gauge indicator or amplifier compatible with a roughly 3 mV/V, 350 Ω-class bridge and recalibrate the complete system after installation.

Related MS-1-10K Guides

 
 
 