top of page

Digital Indicators

Choose a digital weight indicator that matches your scale's load cells, environment and data connections. Compare A&D AD-4328, Brecknell SBI-210 and Cardinal 190 Storm readouts for general weighing, checkweighing and replacement work. Check load-cell drive, enclosure protection, power and mounting before ordering, and distinguish indicator approval from approval of the complete weighing system.

Match the readout to the load-cell system

A replacement indicator needs more than the right display. Record the existing model, scale capacity, displayed increment, number of load cells, bridge resistance and rated output in mV/V. Check the indicator's excitation voltage, supported signal range, wiring arrangement and calibration requirements. A connector that fits physically may have a different pinout.

Choose the A&D AD-4328 for panel or desktop weighing

The A&D AD-4328 has 14.2 mm red LED digits and supports desktop or panel mounting. Its front panel is protected to IP65; that specification should not be treated as an IP65 rating for the entire installed assembly. A&D lists comparator output and interface options for weighing and simple batching. Confirm which option board your application needs, since optional communications and relay hardware are not automatically included. The listed US package includes an AC adapter.

Use the Brecknell SBI-210 for non-trade weighing

The Brecknell SBI-210 drives up to four 350-ohm load cells and has a 1.5-inch backlit LCD. USB virtual-COM and RS-232 ports support connection to a compatible computer or printer. It includes an external power supply and can also operate on six AA batteries, purchased separately.

Checkweighing, counting, accumulation and hold functions suit general weighing tasks. Brecknell identifies the SBI-210 as non-legal-for-trade, so it should not be selected merely because another model in the brand has NTEP approval.

Compare the Cardinal 190 Storm for washdown areas

The Cardinal 190 Storm has an IP69K-rated enclosure, capacitive-touch keys and a 1-inch ColorZONE display that changes color for under, acceptable and over-target weights. It provides 5.18 VDC excitation for up to six 350-ohm load cells and includes bidirectional RS-232. Check the installation's cable entries and all connected components for the cleaning conditions. Rechargeable-battery equipment is optional on the listed AC-powered configuration.

Plan connection, calibration and trade use

Match scale cables and connectors by wiring and interface, then confirm the printer or software protocol. Neither RS-232 nor USB alone guarantees compatibility. NTEP approval of an indicator does not approve the entire installed scale; review the exact system through legal-for-trade weighing requirements before commercial use.

Allow for setup and calibration after changing a readout. Contact All Scales USA at (832) 766-5410 with the indicator and load-cell labels, connector photos and required functions, or review Houston-area scale calibration.

bottom of page