(832) 766-5410
(281) 656-2666
(832) 290-3120
All Scales USA · Cypress, TX · Industrial scales & Houston calibration
Load Cells
Find replacement shear-beam, S-type and compression load cells for floor scales, tension systems, tanks and hoppers. Compare the exact cell model, rated capacity, mounting pattern and electrical output before ordering. The range includes alloy-steel and stainless-steel designs, with different cable and hardware packages. A matching capacity alone does not establish compatibility.
Start with the existing cell and mounting drawing
Record the complete model from the load-cell label, its rated capacity and the scale or vessel it supports. Compare body dimensions, mounting-hole spacing, loading direction, thread size and installed height. Keep the original mounting design in mind: a shear beam, S-type cell and compression disk transfer load differently. Similar photographs or overlapping model names do not establish a drop-in replacement.
Compare alloy and stainless shear beams
The MNM Scales GX-1-1K is a 1,000 lb alloy-steel shear beam. The GX-1-5K with foot and spacer is a 5,000 lb alloy-steel version supplied with a 20 ft cable. Check the individual listing for included hardware; packages sharing the GX-1 name can differ.
For a stainless-steel assembly, compare the GX-1-SH-4k 4,000 lb shear beam. Its listed specifications include 3.00 mV/V nominal output, 10 V excitation and a 6 m cable, with a foot and spacer included. Confirm the sealing specification required by your cleaning process. Stainless construction alone does not define a washdown rating.
Separate tension and compression requirements
The MS-1-10K S-type load cell is a 10,000 lb alloy-steel sensor with 3.00 mV/V nominal output and a 20 ft cable. This listing supplies the cell and cable; the indicator and suspension hardware are separate. Confirm the thread and installation requirements before selecting hardware, or compare the contents of S-type scale kits.
The LPD-CT-100K compression disk is listed at 100,000 lb with 4 mV/V output. It requires a suitable compression mounting arrangement. Check its drawing and the receiving instrument's input range; its output differs from the 3 mV/V cells above.
Check the electrical path and approval requirements
Match rated output, allowed excitation, bridge resistance, wire functions and cable length to the weight indicator and junction box. Confirm wiring from the exact documentation rather than color alone. For mechanical replacements, compare scale feet and hardware against the original assembly.
For commercial use, verify the exact component certificates and finished system requirements through NTEP legal-for-trade scales. A component certificate does not certify every assembled scale. Plan calibration and performance checks after replacement. Call All Scales USA at (832) 766-5410 with the cell label, mounting measurements and indicator model.